products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Grout Glue
Created with Pixso.

CET-2002P Polyurethane Adhesive For Piezo Sensors

CET-2002P Polyurethane Adhesive For Piezo Sensors

Brand Name: Enviko
Model Number: CET-2002P
Payment Terms: T/T
Detail Information
Place of Origin:
China
Packaging Details:
4 kg/set
Highlight:

Piezo Sensors Polyurethane Adhesive

,

Piezo Sensors curing adhesive

,

polyurethane glue For Piezo Sensors

Product Description

CET-2002P

Polyurethane Adhesive for Piezo Sensors

 

YD-2002P is a solvent-free, environmentally friendly cold-curing adhesive used for encapsulating or surface bonding of piezo traffic sensors.

 

Specifications:

Package Size: 4 kg/set

 

Usage Instructions:

Mix components A and B thoroughly using an electric drill for 1-2 minutes.

 

Experimental Data:

YD-2002P is used for encapsulation and may occasionally exhibit sedimentation, especially if stored for a long period or at low temperatures. However, sedimentation can be easily dispersed using an electric drill with a wide blade.

  • Color: Black
  • Resin Density: 1.95
  • Curing Agent Density: 1.2
  • Mixture Density: 1.86
  • Working Time: 5-10 minutes
  • Application Temperature Range: 0°C to 60°C
  • Mixing Ratio (by weight): A:B = 6:1

 

Testing Standards:

  • National Standard: GB/T 2567-2021
  • National Standard: GB 50728-2011

 

Performance Tests:

  • Compression Test Result: 26 MPa
  • Tensile Test Result: 20.8 MPa
  • Fracture Elongation Test Result: 7.8%
  • Adhesion Strength Test (C45 Steel-Concrete Direct Pull Bond Strength): 3.3 MPa (Concrete cohesive failure, adhesive remained intact)

 

Hardness Test (Shore D Hardness Meter):

  • After 3 days at 20°C-25°C: 61D
  • After 7 days at 20°C-25°C: 75D

 

Important Notes:

  • Do not repack into smaller samples on-site; the adhesive should be used all at once.
  • Laboratory samples can be prepared following precise ratio instructions for testing.

 

 

 

Installation Guide:

1. Sensor Installation Groove Dimensions:

  • Recommended groove width: Sensor width +10mm
  • Recommended groove depth: Sensor height +15mm

 

2. Surface Preparation:

  • Use compressed air to remove dust and debris from the concrete surface.
  • Ensure the concrete surface is dry before application.

 

3. Adhesive Preparation:

  1. Mix components A and B with an electric tool for 1-2 minutes. (Mixing time should not exceed 3 minutes.)
  2. Immediately pour the mixed adhesive into the prepared groove. (Do not leave mixed material in the container for more than 5 minutes.)
  3. Flow Time: At room temperature, the material remains workable for 8-10 minutes.